SETPOINT
2 CONFIGURATION (S2.CF)
Setpoint 2 is not
active unless your meter has dual relay output capabilities. The LED's
will display whether the (S2.CF) is active or not. You may use
Setpoint 2 Configuration (S2.CF) for the following:
* To set setpoint's
active band above or below your chosen value
* To select whether the setpoint operation is latched or unlatched
1. Press the
MENU button until the meter shows "S2.CF".
2.
Press the /DEV
button. The meter shows one of the following:
* "S.1=A" (Active above the setpoint)
* "S.1=B" (Active below the setpoint)
3. Press the /MAX
button to toggle between available choices.
4. Press the /DEV
button again The meter shows one of the following:
* "S.2=L" setpoint 1 to be latched
* "S.2=U" setpoint 1 to be unlatched
5. Press the /MAX
button to toggle between available choices.
6. Press the MENU button to store your selection(s). The
meter momentarily shows "STRD", followed by "S1.DB" (Setpoint
1 Deadband).
SETPOINT
1 DEADBAND (S1.DB)
Setpoint 1 Deadband
(S1.DB) is not active unless your meter has dual relay output capabilities.
The LED's will display whether the (S1.DB) is active or not. To
set the deadband (hysteresis) of Setpoint 1, follow these steps:
1. Press the MENU button until the meter shows "S1.DB".
2. Press the /DEV
button. The meter shows the last previously stored 4-digit number (0000
through 9999) with flashing 4th digit.
3. Press the /MAX
button to change the value of the flashing digit. If you continue to press
the /MAX button,
the flashing digit's value continues to change.
4. Press the /DEV
button to scroll to the next digit.
5. Press the MENU button to store value. The meter momentarily
shows "STRD", followed by "S2.DB" (Setpoint 2 Deadband).
SETPOINT
2 DEADBAND ("S2.DB")
Refer to Table 23-1 for a summary list of menu configuration.
Setpoint 2 Deadband (S2.DB) is not active unless your meter has dual relay
output capabilities. The LED's will display whether the (S2.DB) is active
or not. To set the deadband (hysteresis) of Setpoint 2, follow these steps:
1. Press the MENU button until the meter shows "S2.DB".
2. Press the /DEV
button. The meter shows the last previously stored 4-digit number (0000
through 9999) with flashing 4th digit.
3. Press the /MAX
button to change the value of the flashing digit. If you continue to press
the /MAX button,
the flashing digit's value continues to change.
4. Press the /DEV
button to scroll to the next digit.
5. Press the MENU button to store your selection. "STRD"
momentarily displays, followed by cold junction offset if you have a standard
meter (refer to Section 19) or "OT.CF" (Output Configuration) if
you have analog output capabilities (refer to Section 15).
|